RJV Technologies Ltd

Status

This is a specification. RJV has not built a cluster that spans several substrates, has not instrumented wall outlet power for one, and has not run the benchmark suite below. No figure on this page is a measurement, and the paper contains none. An earlier version of this record described a four node CPU cluster, two dual-GPU nodes and a neuromorphic development board, and a measured 34 per cent reduction in energy cost; RJV operated none of that and produced none of that result, so the description was removed rather than qualified.

What follows is the part that can be built and tested: the interface, the allocation rule, and the acceptance criteria a measurement rig would have to meet before anyone could claim the rule helps.

The descriptor

A substrate is wrapped by an adapter exposing one call:

submit(workload_descriptor) → result | refusal(field)

The descriptor carries five declared fields, and an adapter either honours all five or refuses the one it cannot:

FieldDeclaresRefusal example
graphThe computational graph and its data dependenciesoperator not supported by this device
working_setPeak memory held simultaneously, not device capacityworking set exceeds addressable memory
precisionRequired precision per stage, and where reduction is permittedstage marked exact cannot run reduced
deadlineLatest acceptable completion, absolute or relativepredicted completion exceeds deadline
error_modeWhether the caller can accept a refusal, or requires a result or a failuredevice can only fail quietly for this class

The interface is deliberately narrow. A wider one would let a caller name a device or a kernel, and that leak makes the placement decision upstream of the allocator — after which the metric measures nothing.

The allocation rule

Efficiency(s, w) = Throughput(s, w) / (Power(s, w) × Cost_per_hour(s))

selected = argmax_s Efficiency(s, w) subject to Latency(s, w) ≤ deadline

Throughput is in workload specific units; power is measured at the wall at the utilisation the workload induces, never a package thermal figure; cost is amortised hourly including capital depreciation, energy and operator overhead. Two constraints are part of the rule, not tuning: scores are computed over a window so one sample cannot move work, and a challenger must beat the incumbent by a stated margin before it displaces it, because a rule without hysteresis thrashes between substrates whenever two scores cross. Both the window and the margin are declared in the registry entry, so a reader can see how much of a decision was measurement and how much was tolerance.

The rule is deliberately indifferent in a case worth naming: if one candidate has twice the throughput at twice the power for the same hourly cost, the scores are equal. A rule that broke that tie in favour of the faster device would be a preference for throughput dressed as a measurement.

Acceptance criteria for the measurement rig

The first artefact is the rig, not the allocator. It is accepted when, and only when, four tests pass:

  1. It reproduces its own efficiency score within a stated tolerance across repeated runs of the same workload class on the same device.
  2. It refuses to publish a score whose environment is unrecorded: driver version, runtime version, compiler flags, clock policy, cooling, host configuration.
  3. It reports the utilisation at which the score was measured, and refuses to compare scores measured at different utilisations as though they were the same figure.
  4. It states the power instrument and its sampling interval, and the amortisation period and tariff behind the cost term.

If two runs of the same class on the same device differ by more than the difference the metric is meant to detect, the allocator has nothing to allocate on, and the cheap place to discover that is the rig.

Threats to the metric

Wall power includes the host that feeds the device, so a device measured on an idle host looks better than the same device on a busy one. Shared power domains make attribution ambiguous without a dedicated supply or a stated method. Thermal coupling means sustained throughput depends on what neighbouring kit is doing, so a benchmark in an empty rack does not describe a populated one. Virtualisation overhead varies by substrate and can erase the difference the metric exists to find. And a workload with a hard deadline is placed by the constraint rather than the score, which is acceptable but must be said rather than presented as a triumph of measurement.

Why the metaphor

Cellulose fibres of varying length, diameter and composition are suspended, pressed and dried into a uniform sheet: heterogeneous input, one specification for the product. The proposal is that substrates work the same way — a workload declares what it needs, every substrate that can meet the declaration is a candidate, and the choice between candidates is a measured figure rather than a device type. The metaphor is the design constraint: uniform output, measurable specification, no substrate specific language surviving into the caller.